Additional attenuation:≤0.05dB after testNo damage to cable elements
4
Repeated Bending
IEC 60794-1-2-E6
Bending radius: 20 X diameter of cableCycles:25 cycles
Additional attenuation:≤0.05dB after testNo damage to cable elements
5
Torsion/Twist Test
IEC 60794-1-2-E7
Sample length: 1mAngles: ±180 degreeCycles: 5
Additional attenuation:≤0.05dB after testNo damage to cable elements
6
Bending Test
IEC60794-1-2-E11B
Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles
Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements
7
Waterpenetration Test
IEC 60794-1-2-F5
Height of water column 1m Sample length 3mTest time 24 hours
No water leakage from the opposite of the sample
8
Temperature cycling Test
IEC 60794-1-2-F1
Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2
Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements
No
Item
Test Specification
Test Method
Specification
1
Tensile strength Test
IEC 60794-1-2-E1
Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute
Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements
Additional attenuation:≤0.05dB after testNo damage to cable elements
4
Repeated Bending
IEC 60794-1-2-E6
Bending radius: 20 X diameter of cableCycles:25 cycles
Additional attenuation:≤0.05dB after testNo damage to cable elements
5
Torsion/Twist Test
IEC 60794-1-2-E7
Sample length: 1mAngles: ±180 degreeCycles: 5
Additional attenuation:≤0.05dB after testNo damage to cable elements
6
Bending Test
IEC60794-1-2-E11B
Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles
Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements
7
Waterpenetration Test
IEC 60794-1-2-F5
Height of water column 1m Sample length 3mTest time 24 hours
No water leakage from the opposite of the sample
8
Temperature cycling Test
IEC 60794-1-2-F1
Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2
Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements
No
Item
Test Specification
Test Method
Specification
1
Tensile strength Test
IEC 60794-1-2-E1
Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute
Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements
Additional attenuation:≤0.05dB after testNo damage to cable elements
4
Repeated Bending
IEC 60794-1-2-E6
Bending radius: 20 X diameter of cableCycles:25 cycles
Additional attenuation:≤0.05dB after testNo damage to cable elements
5
Torsion/Twist Test
IEC 60794-1-2-E7
Sample length: 1mAngles: ±180 degreeCycles: 5
Additional attenuation:≤0.05dB after testNo damage to cable elements
6
Bending Test
IEC60794-1-2-E11B
Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles
Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements
7
Waterpenetration Test
IEC 60794-1-2-F5
Height of water column 1m Sample length 3mTest time 24 hours
No water leakage from the opposite of the sample
8
Temperature cycling Test
IEC 60794-1-2-F1
Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2
Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements
No
Item
Test Specification
Test Method
Specification
1
Tensile strength Test
IEC 60794-1-2-E1
Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute
Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements
Additional attenuation:≤0.05dB after testNo damage to cable elements
4
Repeated Bending
IEC 60794-1-2-E6
Bending radius: 20 X diameter of cableCycles:25 cycles
Additional attenuation:≤0.05dB after testNo damage to cable elements
5
Torsion/Twist Test
IEC 60794-1-2-E7
Sample length: 1mAngles: ±180 degreeCycles: 5
Additional attenuation:≤0.05dB after testNo damage to cable elements
6
Bending Test
IEC60794-1-2-E11B
Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles
Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements
7
Waterpenetration Test
IEC 60794-1-2-F5
Height of water column 1m Sample length 3mTest time 24 hours
No water leakage from the opposite of the sample
8
Temperature cycling Test
IEC 60794-1-2-F1
Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2
Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements