GDVV 2G.657A2 (Bow-type) +2×1.5mm^2 Optical Hybrid Cable
- Satisfaction guarantee
- Fast delivery
- Quality assurance
Category: Hybrid FO Cable
Description
cross section

Cable structure and size
Table 1 Cable structure and size
| Item | Unit | Value | ||
| FTTH drop cable | Fiber | / | G657.a2 red | |
| Strength member | / | Steel with glue | ||
| Strength member size (steel wire/glue coating) | mm | 0.43/0.48 (±0.02) | ||
| Drop cable size | mm | 2.1(±0.1)*1.6(±0.1) | ||
| Drop cable sheath | / | LSZH Blue, yellow | ||
| Power cable | Conductor structure | / | 30/0.25±0.01mm | |
| Insulation | Material | / | PVC (red,blue) | |
| Nominal thickness | mm | 0.70 | ||
| Minimum thickness | mm | 0.53 | ||
| Insulation outer diameter | mm | 3.1±0.3 | ||
| Outer sheath | Material | / | PVC Black | |
| Nominal thickness of sheath | mm | 1.0 | ||
| Minimum thickness of sheath | mm | 0.8 | ||
| Finished outer diameter | mm | 9.0±0.3 | ||
| reference weight | kg/km | 118 | ||
Performance requirements of optical and electrical hybrid cables
Table 2.Transmission requirements
| Item | Details | Requirements |
| Attenuation coefficient | Maximum value at 1310nm | 0.4 dB/km |
| Maximum value at 1550nm | 0.3 dB/km | |
| Cutoff wavelength | ≤1260nm | |
Table 3.Electrical requirements
| Rated voltage | V | 300/500 |
| Minimum bending radius | mm | 90 |
| Pressure test | 2.0kV AC,5min | No breakdown |
Table 4. Temperature requirements and others
| Operating temperature | -40℃~90℃ |
| Minimum installation temperature | -20℃ |
| Storage and transportation temperature | -40℃~60℃ |
| Application scenario | Indoor&Outdoor |
| Design life | ≥15 years |
| Guideline | IEC 60794,IEC 60332-1, IEC 60332-3 |
Mechanical & Environmental Requirements for drop cables
| No | Item | Test Specification | Test Method | Specification |
| 1 | Tensile strength Test | IEC 60794-1-2-E1 | Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute | Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements |
| 2 | Crush Test | IEC 60794-1-2-E3 | Load: 450 N/10cmDuration time: 1 minuteTest number: 3 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 3 | Impact Test | IEC 60794-1-2-E4 | Impact energy: 1JRadius: 300mmImpact points: 3Impact number: 1 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 4 | Repeated Bending | IEC 60794-1-2-E6 | Bending radius: 20 X diameter of cableCycles:25 cycles | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 5 | Torsion/Twist Test | IEC 60794-1-2-E7 | Sample length: 1mAngles: ±180 degreeCycles: 5 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 6 | Bending Test | IEC60794-1-2-E11B | Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles | Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements |
| 7 | Waterpenetration Test | IEC 60794-1-2-F5 | Height of water column 1m Sample length 3mTest time 24 hours | No water leakage from the opposite of the sample |
| 8 | Temperature cycling Test | IEC 60794-1-2-F1 | Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2 | Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements |
| No | Item | Test Specification | Test Method | Specification |
| 1 | Tensile strength Test | IEC 60794-1-2-E1 | Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute | Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements |
| 2 | Crush Test | IEC 60794-1-2-E3 | Load: 450 N/10cmDuration time: 1 minuteTest number: 3 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 3 | Impact Test | IEC 60794-1-2-E4 | Impact energy: 1JRadius: 300mmImpact points: 3Impact number: 1 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 4 | Repeated Bending | IEC 60794-1-2-E6 | Bending radius: 20 X diameter of cableCycles:25 cycles | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 5 | Torsion/Twist Test | IEC 60794-1-2-E7 | Sample length: 1mAngles: ±180 degreeCycles: 5 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 6 | Bending Test | IEC60794-1-2-E11B | Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles | Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements |
| 7 | Waterpenetration Test | IEC 60794-1-2-F5 | Height of water column 1m Sample length 3mTest time 24 hours | No water leakage from the opposite of the sample |
| 8 | Temperature cycling Test | IEC 60794-1-2-F1 | Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2 | Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements |
| No | Item | Test Specification | Test Method | Specification |
| 1 | Tensile strength Test | IEC 60794-1-2-E1 | Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute | Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements |
| 2 | Crush Test | IEC 60794-1-2-E3 | Load: 450 N/10cmDuration time: 1 minuteTest number: 3 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 3 | Impact Test | IEC 60794-1-2-E4 | Impact energy: 1JRadius: 300mmImpact points: 3Impact number: 1 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 4 | Repeated Bending | IEC 60794-1-2-E6 | Bending radius: 20 X diameter of cableCycles:25 cycles | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 5 | Torsion/Twist Test | IEC 60794-1-2-E7 | Sample length: 1mAngles: ±180 degreeCycles: 5 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 6 | Bending Test | IEC60794-1-2-E11B | Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles | Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements |
| 7 | Waterpenetration Test | IEC 60794-1-2-F5 | Height of water column 1m Sample length 3mTest time 24 hours | No water leakage from the opposite of the sample |
| 8 | Temperature cycling Test | IEC 60794-1-2-F1 | Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2 | Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements |
| No | Item | Test Specification | Test Method | Specification |
| 1 | Tensile strength Test | IEC 60794-1-2-E1 | Sample length: No less than 50 metersLoad: 0.5*Cable weightDuration time:1 minute | Fiber strain:≤0.4%Additional attenuation:≤0.15dB No damage to cable elements |
| 2 | Crush Test | IEC 60794-1-2-E3 | Load: 450 N/10cmDuration time: 1 minuteTest number: 3 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 3 | Impact Test | IEC 60794-1-2-E4 | Impact energy: 1JRadius: 300mmImpact points: 3Impact number: 1 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 4 | Repeated Bending | IEC 60794-1-2-E6 | Bending radius: 20 X diameter of cableCycles:25 cycles | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 5 | Torsion/Twist Test | IEC 60794-1-2-E7 | Sample length: 1mAngles: ±180 degreeCycles: 5 | Additional attenuation:≤0.05dB after testNo damage to cable elements |
| 6 | Bending Test | IEC60794-1-2-E11B | Mandrel diameter: 20 X diameter of cableTurn number: 4Number ofcycles: 3 cycles | Additional attenuation:≤0.05dB After testNo damage to outer jacket and inner elements |
| 7 | Waterpenetration Test | IEC 60794-1-2-F5 | Height of water column 1m Sample length 3mTest time 24 hours | No water leakage from the opposite of the sample |
| 8 | Temperature cycling Test | IEC 60794-1-2-F1 | Temperature step: +20°C ^-20°C ^+70°C^+20°CTime per each step: 12 hoursCycles: 2 | Attenuation variation for referencevalue (the attenuation to bemeasured before test at +20±3°C) ≤0.15dB/km(1550nm)No damage to outer jacket and inner elements |
Flame retardant requirements
| Item | Unit | Technical Requirements |
| Cable flame test | – | IEC 60332-1, IEC 60332-3-24 |